During installation and commissioning of our oil mist separator – whether by our technicians or your own staff – Therefore it depends on good preparation and quick implementation, so costly downtime of the turbine can be avoided.
For this reason, Franke filter plans during the bid phase all the necessary connections to an existing flanges in the correct position, so that the assembly site as quickly and easily runs. The site of the filter system is variable depending on the requirements and space.
The site – almost freely selectable
The easiest and most cost-effective installation of the oil mist separator is directly next to the turbine to the oil tank. In this case, the required geodetic height by the length-adjusted standpipe already complied. The recirculation of the filtered oil lubrication is done automatically by the integrated return line. The installation of additional pipes is limited to any clean air discharge into the open. In addition to this installation option is the best option, to attach the filter with the help of an additional rack next to the oil tank at the height of the turbine. Even installations outside the turbine hall or outdoors can be realized, if inside the turbine hall or not there is enough space. Here, the designed pipe laying for the raw air and the return line complex. The most important aspect for the correct operation of all components is the already mentioned geodetic height, which are always adhered to.
No matter what type of installation which is appropriate for your application – We like to take over the installation and commissioning of the monitor.
Oil return – expensive pipe laying save
The return of filtered lubricating oil in the lubricating oil tank of the turbine is in the best case on the stand-pipe integrated return line. If larger distances are bridged, Franke filter shall have developed reliable interim solutions. The geodetic height is always in view, , the lubricating oil via siphon or a small intermediate tank, which is equipped as required with each pump, be fed back into the tank.
Even with very limited space on the oil tank we can make it nearly always, accommodate our compact and exactly fitting oil mist separator at this location. If the times do not work, You can still save time and material.
In designing our system we have been told: "Costly clean-air installation of pipes into the open? This does not have to. "The separation of more than 99,9% and the associated cost efficiency of our plants this point superfluous. The discharged air is so clean and pure, that they are directly mounted on the clean air vent in the environment, as z. B. the turbine hall, can be conducted.